GOTTOGPOWER 100~1200kVA High Frequency Modular Online UPS
The GTM-100 Series 100–1200kVA modular UPS is a fully digital, high-efficiency (≥97%) three-phase online double-conversion uninterruptible power supply supporting scalable expansion up to 3.2MVA — delivering hyperscale data center UPS protection, intelligent self-diagnosis, lithium battery UPS compatibility, and IoT-enabled 10-inch touch LCD management for the world's most demanding critical power infrastructure applications.
Classification:
Modular UPS
Inquire Now
Downloads:
Product Description
1. Product Overview
The GTM-100 Series 100–1200kVA modular UPS is a flagship-grade, high-power uninterruptible power supply system developed by GOTTOGPOWER (ANHUI) CO., LTD for mega data center UPS, industrial UPS, and large-scale enterprise power protection applications. Operating on the Online Double Conversion (3P/3P) principle, this large modular UPS system delivers fully clean, regulated power across a scalable range from 100kVA to 1200kVA per cabinet — and supports system expansion up to 3.2MVA, making it the definitive high-capacity UPS solution for hyperscale data centers and mission-critical national infrastructure.
With a peak efficiency of ≥97%, the GTM-100 Series modular UPS minimizes data center cooling loads and reduces total cost of ownership across the entire UPS system lifecycle. Built around a fully digital control architecture, this three-phase online UPS offers flexible, robust performance with intelligent self-diagnosis, comprehensive fault recording, and large-capacity event history storage — empowering facility managers with complete UPS visibility and predictive maintenance capability. The GTM-100 Series modular UPS also supports battery connection without Neutral, enabling lithium battery UPS compatibility and simplified high-voltage DC battery configurations.
2. Key Features
- Mega Data Center UPS Capacity — Up to 3.2MVA Maximum System: The GTM-100 Series modular UPS supports parallel expansion to 3.2MVA, delivering the highest per-system UPS capacity available for hyperscale data center UPS and cloud computing power infrastructure.
- Fully Digital Control UPS Architecture: Advanced fully digital control technology delivers flexible, robust modular UPS operation with precise power regulation, fast dynamic response (<5% load transient; <20ms recovery), and superior three-phase balance management.
- Intelligent UPS Self-Diagnosis & Fault Recording: Built-in intelligent self-diagnosis engine with rich fault event recording and large-capacity history storage enables proactive UPS maintenance, rapid fault analysis, and minimized unplanned downtime.
- 10-Inch IoT Touch LCD UPS Display: Large 10-inch color touch LCD with integrated IoT functions provides real-time UPS monitoring, remote management, DCIM integration, and intuitive system configuration for large-scale modular UPS installations.
- Battery Connection Without Neutral — Lithium Battery UPS Ready: Supports battery neutral-free wiring, enabling seamless compatibility with lithium battery UPS systems and high-voltage battery cabinets for next-generation energy storage integration.
- High Reliability — Component-Level UPS Protection: Multi-tier protection at system, board, and component levels ensures maximum modular UPS reliability in demanding environments with wide temperature and humidity variation.
- ≥97% Online UPS Efficiency: Industry-leading three-phase UPS efficiency rating of ≥97% significantly reduces heat dissipation, lowers PUE, and decreases total energy cost for large-scale UPS data center deployments.
3. Typical Applications
The GTM-100 Series 100–1200kVA modular UPS system is engineered for the world's most demanding power continuity applications:
- Hyperscale & Mega Data Center UPS — Scalable modular UPS power protection for Tier III/IV data centers, colocation facilities, hyperscale cloud campuses, and edge computing nodes requiring 3P/3P online double-conversion UPS up to 3.2MVA.
- Financial & Capital Markets Infrastructure — Zero-tolerance power protection for algorithmic trading platforms, core banking systems, clearing networks, and financial data centers where any power interruption incurs regulatory and commercial risk.
- Government & National Critical Infrastructure — Uninterruptible power supply for national data centers, military command systems, emergency management centers, and e-government digital infrastructure.
- Telecommunications & 5G Network UPS — Three-phase modular UPS protection for carrier-grade telecom exchange centers, 5G base station hubs, and national backbone network facilities.
- Industrial UPS & Smart Manufacturing — High-capacity online UPS for large-scale industrial automation, process control, semiconductor fabrication, and smart factory infrastructure.
- Healthcare & Pharmaceutical UPS — Reliable uninterruptible power supply for hospital data centers, clinical research facilities, medical imaging systems, and pharmaceutical manufacturing.
- Energy & Power Grid Infrastructure — Modular UPS integration for renewable energy management systems, smart grid control centers, power dispatch centers, and energy storage platforms.
4. Technical Specifications
Models: GTM600/100 · GTM800/100 · GTM1000/100 · GTM1200/100
Parameter | GTM600/100 600kVA/600kW | GTM800/100 800kVA/800kW | GTM1000/100 1000kVA/1000kW | GTM1200/100 1200kVA/1200kW |
Main Input | ||||
Input | 3P5W (3P+N+PE) | |||
Rated Voltage | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | |||
Rated Frequency | 50/60Hz | |||
Input PF | >0.99 | |||
Current Distortion | THDi < 3% (100% Linear load) | |||
Voltage Range | 304~478VAC(L-L) full load; 304~228VAC(L-L) derated 100% to 50% | |||
Freq. Range | 40–70Hz | |||
Battery | ||||
Rated Voltage | 3 Wires: +240VDC / 2 Wires: 480VDC | |||
Charging Capacity | Max. 15%* Pout | |||
Charging Accuracy | ±1% | |||
Bypass | ||||
Rated Voltage | 380/400/415VAC(L-L) | |||
Voltage Range | Range: −40%~+25%; Settable, default −20%~+15% | |||
Overload | <110%, continuous; 110%<load<125%, 10 min; 125%<load<150%, 1 min | |||
Inverter Output | ||||
Rated Voltage | 380/400/415VAC(L-L) | |||
Rated Frequency | 50/60Hz | |||
Output PF | 1 | |||
Voltage Accuracy | ±1.0% | |||
Load Response | <5% (20%→80%→20% step load) | |||
Recovery Time | <20ms (0%→100%→0% step load) | |||
Output THDu | <1% (linear load); <3% (non-linear, IEC 62040-3) | |||
Overload | 110%/1h; 125%/10min; 150%/1min; >150%/200ms | |||
Frequency Accuracy | 0.1% | |||
Synchronize Window | Settable ±0.5Hz–±5Hz, default ±3Hz | |||
Slew Rate | Settable 0.5Hz/s–3Hz/s, default 0.5Hz/s | |||
Crest Factor | 3:1 | |||
Phase Accuracy | 120° ± 0.5° | |||
System | ||||
Efficiency | ≥97% | |||
Display | LED + 10" Touch LCD | |||
IP Degree | IP20 | |||
Safety Certification | IEC62040-1, IEC60950-1 | |||
EMC Certification | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4(EFT); IEC61000-4-5(Surge) | |||
Configuration | USB, RS232, RS485, Dry Contact, Cold Start, Air Filter | |||
Option | SNMP Card, AS400 Card, Parallel Kit, SPD, Top Air Outlet | |||
Environment | 0–40°C (operation); −25–70°C (storage); 0–95% RH (non-condensing) | |||
Noise (@1m) | 72dB @ 100% load; 69dB @ 45% load | |||
Dimensions (W×D×H mm) | ||||
Cabinet (Standard) | 800×1000×2000 | 800×1000×2000 | 1200×1100×2000 | 1200×1100×2000 |
Four-Switch Cabinet (Optional) | 800×1000×2000 | / | / | / |
Module (W×D×H) | 475×705×140 | |||
5. Certifications & Compliance
The GTM-100 Series modular UPS complies with the following international UPS safety, performance, and EMC standards:
- UPS Safety Standard: IEC 62040-1, IEC 60950-1
- UPS EMC Standard: IEC 62040-2
- ESD Immunity: IEC 61000-4-2
- Radiated Susceptibility: IEC 61000-4-3
- Electrical Fast Transient / Burst: IEC 61000-4-4
- Surge Immunity: IEC 61000-4-5
6. Interfaces & Optional Accessories
Standard UPS Interfaces
USB, RS232, RS485, Dry Contact, Cold Start, Air Filter — enabling seamless integration with DCIM platforms, BMS, building automation systems, and centralized UPS network management infrastructure.
Optional UPS Accessories & Add-ons
- SNMP Card — enables SNMP v1/v2/v3 network UPS monitoring and integration with NMS or DCIM platforms for centralized large-scale UPS management.
- AS400 Card — provides UPS compatibility with IBM AS400 / iSeries mission-critical enterprise server environments.
- Parallel Kit — supports modular UPS parallel operation for scalable N+X redundancy and non-disruptive capacity expansion up to 3.2MVA.
- SPD (Surge Protection Device) — additional surge protection for UPS input and output circuits in high-lightning-risk environments.
- Top Air Outlet — alternative top-exhaust airflow configuration for optimized hot-aisle/cold-aisle data center UPS airflow management.