GOTTOGPOWER 50~600kVA Modular Online Uninterruptible Power Supply
The GTM-50 Series 50–600kVA modular UPS is a high-efficiency (≥97%), three-phase online double-conversion uninterruptible power supply system delivering scalable, redundant power protection for data centers, industrial facilities, financial institutions, and critical infrastructure — featuring high power density, lithium battery UPS compatibility, fault-tolerant thermal management, and comprehensive IEC certification for global deployment.
Classification:
Modular UPS
Inquire Now
Downloads:
Product Description
1. Product Overview
The GTM-50 Series 50–600kVA modular UPS is a high-power, high-efficiency uninterruptible power supply system developed by GOTTOGPOWER (ANHUI) CO., LTD. Designed for large-scale data center UPS, industrial UPS, and enterprise power protection applications, the GTM-50 Series modular UPS supports online double-conversion (3P/3P) operation across a scalable power range from 50kVA to 600kVA. With a best-in-class efficiency rating of ≥97%, the GTM-50 modular UPS system significantly reduces energy consumption and total cost of ownership compared to conventional UPS solutions.
As a true modular UPS power system, the GTM-50 Series allows capacity expansion without downtime, making it the ideal three-phase UPS solution for mission-critical environments requiring N+1 redundancy, scalable power infrastructure, and long-term investment protection. The GTM-50 Series online UPS is fully compatible with lithium battery UPS configurations, featuring an optional battery neutral-free design that future-proofs your power system for next-generation energy storage.
2. Key Features
- High Power Density Modular UPS: Saves over 10% installation space compared to similar UPS products, enabling more efficient data center power density management and rack space optimization.
- Lithium Battery UPS Compatible: Optional battery neutral-free design ensures seamless compatibility with lithium battery UPS systems, reducing battery cabinet footprint and total weight.
- Ultimate Reliability — System, Board & Component Protection: Comprehensive three-level protection architecture (system, board, and component) delivers the highest modular UPS reliability for critical power infrastructure.
- Large LCD Touch Screen UPS Interface: Color graphical LCD touch screen (7-inch on GTM200/50; 10-inch on GTM300–600/50) provides intuitive UPS monitoring, real-time load management, and user-friendly configuration.
- Highly Integrated PCB Design: Optimized PCB integration improves UPS module assemblability, lowers manufacturing variance, and reduces field maintenance human error.
- Fault-Tolerant Thermal Management: Optimized UPS thermal layout with elevated design margin — the modular UPS system continues to support up to 70% load output even in the event of a single fan failure, ensuring uninterrupted power supply.
- ≥97% UPS Efficiency: Industry-leading online UPS efficiency rating of ≥97% minimizes heat dissipation and lowers total operating cost for large-scale UPS installations.
3. Typical Applications
The GTM-50 Series modular UPS system is purpose-built for large-scale, mission-critical power protection environments:
- Data Center UPS & Cloud Infrastructure — Provides scalable, redundant uninterruptible power supply for hyperscale data centers, colocation facilities, and cloud computing infrastructure.
- Financial & Banking Systems — Protects high-frequency trading platforms, core banking systems, and payment processing networks with zero-interruption power continuity.
- Government & Public Safety — Ensures uninterrupted power supply for government data centers, emergency command centers, and national critical infrastructure.
- Industrial UPS Applications — Supports manufacturing automation, process control systems, and industrial IoT infrastructure requiring three-phase online UPS protection.
- Telecommunications & Broadcasting — Safeguards telecom base stations, broadcast transmission equipment, and media production facilities.
- Healthcare & Medical Facilities — Delivers reliable UPS power protection for hospital critical care systems, medical imaging equipment, and life-support devices.
- Transportation & Smart Infrastructure — Powers rail signaling systems, airport operations, traffic management, and smart city infrastructure.
- Energy & Renewable Power Systems — Integrates with renewable energy UPS systems, energy storage solutions, and smart grid power management platforms.
4. Technical Specifications
Models: GTM200/50 · GTM300/50 · GTM400/50 · GTM500/50 · GTM600/50
Parameter | GTM200/50 200kVA/200kW | GTM300/50 300kVA/300kW | GTM400/50 400kVA/400kW | GTM500/50 500kVA/500kW | GTM600/50 600kVA/600kW |
Main Input | |||||
Input | 3P5W (3P+N+PE) | ||||
Rated Voltage | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | ||||
Rated Frequency | 50/60Hz | ||||
Input PF | >0.99 | ||||
Current Distortion | THDi < 2% (100% Linear load) | ||||
Voltage Range | 304~478VAC(L-L) full load; 304~228VAC(L-L) derated 100% to 50% | ||||
Freq. Range | 40–70Hz | ||||
Battery | |||||
Rated Voltage | 3 Wires: +240VDC / 2 Wires: 480VDC (default 40 pcs; 30–50 pcs selectable) | ||||
Charging Capacity | 20%*Pout | ||||
Charging Accuracy | ±1% | ||||
Bypass | |||||
Rated Voltage | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | ||||
Voltage Range | Range: −40%~+25%; Settable, default −20%~+15% | ||||
Overload | <110%, continuous; 110%<load<125%, 10 min; 125%<load<150%, 1 min | ||||
Inverter Output | |||||
Rated Voltage | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | ||||
Rated Frequency | 50/60Hz | ||||
Output PF | 1 | ||||
Voltage Accuracy | ±1.0% | ||||
Output THDu | <1% (linear load); <5% (non-linear load) | ||||
Overload | 110%/1h; 125%/10min; 150%/1min; >150%/200ms | ||||
Frequency Accuracy | 0.1% | ||||
Synchronize Window | Settable ±0.5Hz–±5Hz, default ±3Hz | ||||
Slew Rate | Settable 0.5Hz/s–3Hz/s, default 0.5Hz/s | ||||
Crest Factor | 3:1 | ||||
Phase Accuracy | 120° ± 0.5° | ||||
System | |||||
Efficiency | ≥97% | ||||
Display | LED + 7" Touch LCD | LED + 10" Touch LCD | LED + 10" Touch LCD | LED + 10" Touch LCD | LED + 10" Touch LCD |
IP Degree | IP20 | ||||
Safety Certification | IEC62040-1, IEC60950-1 | ||||
EMC Certification | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4(EFT); IEC61000-4-5(Surge) | ||||
Performance Certification | IEC62040-3 | ||||
Configuration | USB, RS232, RS485, Dry Contact, Cold Start, Air Filter | ||||
Option | SNMP Card, AS400 Card, Parallel Kit, SPD, Top Air Outlet, APP / Wi-Fi / Bluetooth | ||||
Environment | 0–40°C (operation); −25–70°C (storage); 0–95% RH (non-condensing) | ||||
Wiring Method | Top front wiring; bottom front wiring (optional) | Top front wiring; bottom front wiring (optional) | Top front wiring; bottom front wiring (optional) | Compatible with top & bottom wiring | Compatible with top & bottom wiring |
Noise (@1m) | 68dB @ 100% load; 65dB @ 45% load | ||||
Dimensions (W×D×H mm) | |||||
Cabinet (Standard) | 600×750×1600 | 600×750×2000 | 600×1000×2000 | 1200×850×2000 (four switches by default) | 1200×850×2000 (four switches by default) |
Four-Switch Cabinet (Optional) | 600×850×2000 | 600×850×2000 | / | / | / |
Module (W×D×H) | 440×475×140 | ||||
5. Certifications & Compliance
The GTM-50 Series modular UPS complies with the following international UPS standards and electromagnetic compatibility certifications:
- UPS Safety Standard: IEC 62040-1, IEC 60950-1
- UPS Performance Standard: IEC 62040-3
- UPS EMC Standard: IEC 62040-2
- ESD Immunity: IEC 61000-4-2
- Radiated Susceptibility: IEC 61000-4-3
- Electrical Fast Transient / Burst: IEC 61000-4-4
- Surge Immunity: IEC 61000-4-5
6. Interfaces & Optional Accessories
Standard UPS Interfaces
USB, RS232, RS485, Dry Contact, Cold Start, Air Filter — supporting integration with BMS, DCIM, and building management systems for centralized UPS monitoring.
Optional UPS Accessories & Add-ons
- SNMP Card — enables SNMP-based network UPS monitoring and remote management via NMS or DCIM platforms.
- AS400 Card — ensures UPS compatibility with IBM AS400 / iSeries mission-critical server environments.
- Parallel Kit — supports UPS parallel operation for scalable N+X redundancy and capacity expansion without downtime.
- SPD (Surge Protection Device) — additional surge protection for the UPS input and output circuits.
- Top Air Outlet — alternative top-exhaust airflow option for optimized hot-aisle/cold-aisle data center UPS deployment.
- APP / Wi-Fi / Bluetooth — wireless UPS monitoring and control via mobile devices for on-site and remote management.