GOTTOGPOWER Modular UPS Online With Lithium Battery 10~150kVA
The GTM-10/20/25/30-Li Series 10–150kVA lithium-battery modular UPS is a next-generation online double-conversion uninterruptible power supply featuring native lithium battery UPS support with supercharging, compatibility with both lithium-ion and sodium-ion batteries, 30kW/2U extreme power density, battery neutral-free wiring, built-in Ethernet IoT management, and THDi < 2% input quality — delivering scalable, lightweight, high-reliability modular UPS protection for edge data centers, enterprise IT, healthcare, telecommunications, and distributed critical power infrastructure.
Classification:
Modular UPS
Inquire Now
Product Description
1. Product Overview
The GTM-10/20/25/30-Li Series 10–150kVA lithium-battery modular UPS is a next-generation uninterruptible power supply system developed by GOTTOGPOWER (ANHUI) CO., LTD, purpose-built for deployments demanding both the flexibility of a modular UPS and the superior performance of lithium battery UPS technology. This lithium modular UPS system delivers Online Double Conversion (3P/3P, 3P/1P, 1P/1P) power protection across a scalable range from 10kVA to 150kVA, making it an ideal rack-mount UPS or standalone online UPS for small-to-medium data centers, edge computing sites, and distributed enterprise power infrastructure.
As a dedicated lithium battery UPS, the GTM-Li Series supports supercharging for high-capacity lithium battery packs, enables battery connection without Neutral for simplified high-voltage DC wiring, and delivers extreme power density of 30kW in a compact 2U module — minimizing rack space consumption while maximizing UPS system availability. With an Ethernet port built into the standard configuration alongside the 7-inch IoT touch LCD, this modular UPS system is designed for seamless integration into modern DCIM and smart building management platforms.
2. Key Features
- Lithium Battery UPS Support with Supercharging: The GTM-Li Series modular UPS is engineered specifically for lithium battery UPS configurations, supporting high-rate supercharging to rapidly restore high-capacity lithium battery packs and minimize downtime risk after a discharge event. It is also compatible with sodium-ion batteries, providing flexible support for emerging battery technologies.
- Battery Connection Without Neutral — Simplified High-Voltage DC Wiring: Supports neutral-free battery wiring, enabling cleaner, lower-cost lithium battery UPS cabinet integration and compatibility with modern HVDC energy storage architectures.
- Extreme 30kW/2U Power Density Modular UPS: Delivers 30kW of UPS output power in a 2U rack module, achieving best-in-class power density for space-constrained rack-mount UPS applications and reducing total infrastructure footprint.
- Zero-Disassembly 19-Inch Rack-Mount UPS or Standalone: Installs directly into a standard 19-inch rack without disassembly, or deploys as a standalone floor UPS — no tools required, supporting flexible data center UPS and office UPS deployment scenarios.
- 7-Inch IoT Touch LCD with Ethernet Interface: Integrated 7-inch color touch LCD with IoT functions and a built-in Ethernet port enables real-time UPS monitoring, remote management, and DCIM/BMS integration for smart power infrastructure.
- High Reliability — Component-Level UPS Protection: Multilayer protection at system, board, and component levels with strong environmental adaptability ensures maximum lithium modular UPS reliability across wide temperature and humidity ranges.
- THDi < 2% Input Current Distortion: Ultra-low input current distortion (THDi < 2%) minimizes harmonic pollution on the supply network, making the GTM-Li Series modular UPS ideal for sensitive shared-power environments.
3. Typical Applications
The GTM-10/20/25/30-Li Series lithium-battery modular UPS is optimized for distributed, space-constrained, and weight-sensitive critical power protection environments:
- Edge Data Center & Micro Data Center UPS — Compact lithium modular UPS power protection for edge computing nodes, micro data centers, and CDN PoP sites requiring high power density in limited rack space.
- Enterprise IT & Server Room UPS — Scalable rack-mount UPS or standalone online UPS for SME server rooms, network equipment rooms, and enterprise IT infrastructure requiring lithium battery UPS longevity and fast recharge.
- Finance & Banking Branch UPS — Reliable lithium battery uninterruptible power supply for bank branch offices, ATM networks, and financial terminal infrastructure.
- Government & Smart City Infrastructure — Online double-conversion UPS protection for government edge computing, smart city IoT hubs, traffic management systems, and public safety networks.
- Healthcare & Clinical UPS — Lightweight lithium modular UPS for hospital ward equipment rooms, diagnostic device power protection, and clinical IT systems where weight and footprint are constrained.
- Telecommunications & 5G Edge UPS — Three-phase modular UPS protection for 5G base station edge sites, telecom exchange rooms, and distributed antenna system power infrastructure.
- Education & Research Facilities — Scalable modular UPS for campus data centers, research computing facilities, and e-learning infrastructure requiring flexible, low-maintenance lithium battery UPS solutions.
4. Technical Specifications
Note: All models share Online Double Conversion (3P/3P, 3P/1P, 1P/1P) topology. Battery voltage and efficiency vary by sub-series as indicated in the table below.
Parameter | M10E-Li | M20E-Li | M25E-Li | M30E-Li | |||||||
GT020/10E 20kVA | GT040/10E 40kVA | GT060/10E 60kVA | GT040/20E 40kVA | GT080/20E 80kVA | GT120/20E 120kVA | GT050/25E 50kVA | GT100/25E 100kVA | GT150/25E 150kVA | GT120/30E 120kVA | GT150/30E 150kVA (5+1) | |
Main Input | |||||||||||
Input | 3P5W (3P+N+PE) | ||||||||||
Rated Voltage | 380/400/415VAC(L-L) | ||||||||||
Rated Frequency | 50/60Hz | ||||||||||
Input PF | >0.99 | ||||||||||
Current Distortion | THDi < 2% (100% Linear load) | ||||||||||
Voltage Range | 304~478VAC(L-L) full load; 304~228VAC(L-L) derated 100% to 50% | 304~478VAC(L-L) full load; 304~228VAC(L-L) derated 100% to 50% | 304~478VAC(L-L) full load; 304~228VAC(L-L) derated 100% to 50% | 324~478VAC(L-L) full load; 324~228VAC(L-L) derated 100% to 50% | |||||||
Freq. Range | 40–70Hz | ||||||||||
Battery | |||||||||||
Rated Voltage | 2 Wires: 256–512 VDC | 2 Wires: default 512 VDC | 2 Wires: default 512 VDC | 2 Wires: default 512 VDC | |||||||
Charging Capacity | 50% × Pout (limited by input current) | ||||||||||
Charging Accuracy | ±1% | ||||||||||
Bypass | |||||||||||
Rated Voltage | 380/400/415VAC(L-L) | ||||||||||
Voltage Range | Range: −40%~+25%; Settable, default −20%~+15% | ||||||||||
Overload | <110%, continuous; 110%<load<125%, 10 min; 125%<load<150%, 1 min | ||||||||||
Inverter Output | |||||||||||
Rated Voltage | 380/400/415VAC(L-L) | ||||||||||
Rated Frequency | 50/60Hz | ||||||||||
Output PF | 1 | ||||||||||
Voltage Accuracy | ±1.0% | ||||||||||
Output THDu | <1% (linear load); <5% (non-linear, IEC 62040-3) | ||||||||||
Overload | 110%/1h; 125%/10min; 150%/1min; >150%/200ms | ||||||||||
Frequency Accuracy | 0.1% | ||||||||||
Synchronize Window | Settable ±0.5Hz–±5Hz, default ±3Hz | ||||||||||
Slew Rate | Settable 0.5Hz/s–3Hz/s, default 0.5Hz/s | ||||||||||
Phase Accuracy | 120° ± 0.5° | ||||||||||
System | |||||||||||
Efficiency (Normal) | Max 96.0% | Max 96.6% | Max 96.6% | Max 96.6% | |||||||
Display | LED + 7" Touch LCD | ||||||||||
IP Degree | IP20 | ||||||||||
Safety Certification | IEC62040-1, IEC60950-1 | ||||||||||
EMC Certification | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4(EFT); IEC61000-4-5(Surge) | ||||||||||
Configuration | USB, RS232, RS485, Dry Contact, Cold Start, Air Filter, Ethernet Port | ||||||||||
Option | SNMP Card, AS400 Card, SPD, Parallel Kit | ||||||||||
Environment | 0–40°C (operation); −25–70°C (storage); 0–95% RH (non-condensing) | ||||||||||
Noise (@1m) | 65dB @ 100% load; 62dB @ 45% load | ||||||||||
Dimensions & Weight | |||||||||||
Cabinet Slots | 2-Slots | 4-Slots (10kVA modules) | 4-Slots | 6-Slots | |||||||
Body Dim. (default) | 442×711×307 (7U) | 442×710×485 (11U) | 442×661×705 (16U) | 442×661×906 (20U) | |||||||
MAX Dimension | 442×751×397 | 442×751×575 | 442×841×797 | 442×841×976 | |||||||
Module Weight (kg) | 12.65 | 12.85 | 13.95 | 13.95 | |||||||
Cabinet Weight (kg) | 39 | 52 | 64 | 88 | |||||||
5. Certifications & Compliance
The GTM-10/20/25/30-Li Series lithium modular UPS complies with the following international standards:
- UPS Safety Standard: IEC 62040-1, IEC 60950-1
- UPS EMC Standard: IEC 62040-2
- ESD Immunity: IEC 61000-4-2
- Radiated Susceptibility: IEC 61000-4-3
- Electrical Fast Transient / Burst: IEC 61000-4-4
- Surge Immunity: IEC 61000-4-5
6. Interfaces & Optional Accessories
Standard UPS Interfaces
USB, RS232, RS485, Dry Contact, Cold Start, Air Filter, Ethernet Port — the built-in Ethernet port enables direct network UPS management without additional adapters, supporting DCIM and smart building management system integration.
Optional UPS Accessories
- SNMP Card — enables SNMP-based network UPS monitoring and integration with NMS or DCIM platforms.
- AS400 Card — provides UPS compatibility with IBM AS400 / iSeries server environments.
- SPD (Surge Protection Device) — additional surge protection for UPS input/output circuits.
- Parallel Kit — supports modular UPS parallel redundancy (N+1) for scalable capacity expansion.