Getong Energy
+
  • GOTTOGPOWER-Tower-UPS-Online-UPS-High-Frequency-UPS.png
  • 未标题-1(1773631103820).png

GOTTOGPOWER 10~200kVA Three-Phase Tower UPS

The GT Tower Series 10–200kVA three-phase tower UPS delivers 3P/3P online double-conversion power protection with ≥96% efficiency, THDi <2%, standard built-in quad switching (input/bypass/output/maintenance), 7-inch color touchscreen, intelligent black-box fault recording, and mobile caster-equipped tower design — providing a complete, enterprise-ready three-phase uninterruptible power supply for data centers, finance, government, industrial, healthcare, and telecommunications infrastructure across 11 models.

Classification:

Tower UPS


Inquire Now

Product Description

1. Product Overview

The GT Tower Series 10–200kVA three-phase tower UPS is a high-reliability, full-featured uninterruptible power supply system developed by GOTTOGPOWER (ANHUI) CO., LTD for medium-to-large enterprise, data center, industrial, and critical infrastructure power protection applications. Operating on the 3P/3P Online Double Conversion principle, the GT Tower three-phase UPS delivers continuous, clean power across an 11-model range from 10kVA to 200kVA — all in a robust tower form factor with built-in casters engineered for flexible floor deployment and simplified on-site logistics.

The GT Tower Series three-phase online UPS stands apart through its standard built-in input, bypass, output, and maintenance switches, providing complete operational switching capability without requiring additional external switchgear. Combined with a 7-inch LCD color touchscreen, intelligent black-box fault recording, and multi-level system-board-component protection, the GT Tower UPS delivers enterprise-grade power continuity with the operational transparency and diagnostic depth demanded by mission-critical facility managers.

2. Key Features

  • Standard Built-in Input, Bypass, Output & Maintenance Switches: All four critical switching functions are built into every GT Tower three-phase UPS as standard — eliminating the need for external switchgear, simplifying installation and commissioning, and enabling safe maintenance without interrupting load power.
  • 7-Inch LCD Color Touchscreen UPS Interface: Large 7-inch color LCD touchscreen provides a rich, intuitive real-time display of UPS operating status, load levels, battery health, input/output measurements, and event history for efficient on-site three-phase UPS management.
  • Intelligent Fault Recording — Black Box Function: Built-in black-box function continuously captures event logs, fault sequences, and operational waveform data, enabling rapid and accurate root-cause analysis for minimal MTTR in mission-critical three-phase UPS deployments.
  • Tower UPS with Built-in Casters — Mobile, Flexible Deployment: Integrated casters on the tower chassis allow effortless repositioning and installation of large three-phase UPS units without specialist lifting equipment, reducing deployment time and logistics cost on-site.
  • Multi-Level UPS Protection — System, Board & Component: Three-tier protection architecture at system, board, and component levels ensures maximum three-phase UPS reliability across wide environmental and load variation ranges.
  • THDi < 2% Ultra-Low Input Current Distortion: Less than 2% input current THD at 100% linear load minimizes harmonic pollution on shared power networks, protecting co-located sensitive equipment and maintaining compliance with power quality standards.
  • Flexible Battery Configuration by Model Group: GT010L–GT040L support ±120VDC battery strings (20–50 pcs, Max 50% * Pout charging); GT060–GT200 support ±240VDC strings (30–50 pcs, Max 20% * Pout charging) — enabling tailored backup runtime for each deployment scenario.

3. Typical Applications

The GT Tower Series 10–200kVA three-phase tower UPS is designed for demanding power protection across a broad range of critical industries:

  • Enterprise Data Center UPS — Three-phase online UPS for small-to-medium data centers, virtualization infrastructure, and enterprise server rooms requiring scalable power protection from 10kVA to 200kVA.
  • Finance & Banking UPS — High-reliability three-phase UPS for bank data centers, trading floor infrastructure, core banking systems, and financial data processing centers.
  • Government & Public Sector UPS — Three-phase tower UPS for government data centers, public safety communications, e-government IT infrastructure, and national critical facility power protection.
  • Industrial & Manufacturing UPS — Robust three-phase online UPS for industrial automation, process control, MES systems, and smart factory power continuity.
  • Healthcare & Hospital UPS — Three-phase UPS power protection for hospital data centers, radiology, laboratory information systems, and large-scale medical equipment.
  • Telecommunications & Network Infrastructure UPS — Three-phase tower UPS for telecom exchange centers, enterprise NOCs, ISP core infrastructure, and regional data hubs.
  • Education & Research Institution UPS — Scalable three-phase UPS for university data centers, HPC clusters, scientific computing, and campus IT infrastructure.

4. Technical Specifications

Models: GT010L · GT015L · GT020L · GT030L · GT040L · GT060 · GT080 · GT100 · GT120 · GT150 · GT200

Note: L suffix = long-run external battery variant. GT060–GT200 include built-in battery. Battery voltage and charging power differ between model groups as shown in the table below.

Parameter

GT010L

10kVA

GT015L

15kVA

GT020L

20kVA

GT030L

30kVA

GT040L

40kVA

GT060

60kVA

GT080

80kVA

GT100

100kVA

GT120

120kVA

GT150

150kVA

GT200

200kVA

Main Input

Input

3P5W (3P+N+PE)

Rated Voltage

380/400/415VAC(L-L)

Rated Frequency

50/60Hz

Input PF

>0.99

Current Distortion

THDi < 2% (100% Linear load)

Voltage Range

304~478VAC(L-L) full load; 304~228VAC(L-L) derated 100% to 50%

Freq. Range

40–70Hz

Battery

Rated Voltage

±120 VDC (20–50 pcs selectable)

±120 VDC (20–50 pcs selectable)

±120 VDC (20–50 pcs selectable)

±120 VDC (20–50 pcs selectable)

±120 VDC (20–50 pcs selectable)

±240 VDC (30–50 pcs selectable)

±240 VDC (30–50 pcs selectable)

±240 VDC (30–50 pcs selectable)

±240 VDC (30–50 pcs selectable)

±240 VDC (30–50 pcs selectable)

±240 VDC (30–50 pcs selectable)

Charging Power

Max. 50% * Pout

Max. 50% * Pout

Max. 50% * Pout

Max. 50% * Pout

Max. 50% * Pout

Max. 20% * Pout

Max. 20% * Pout

Max. 20% * Pout

Max. 20% * Pout

Max. 20% * Pout

Max. 20% * Pout

Charging Accuracy

±1%

Bypass

Rated Voltage

380/400/415VAC(L-L)

Voltage Range

Range: −40%~+25%; Settable, default −20%~+15%

Frequency Range

50/60Hz; Settable: ±1Hz, ±3Hz, ±5Hz

Inverter Output

Rated Voltage

380/400/415VAC(L-L)

Rated Frequency

50/60Hz

Output PF

1

Voltage Accuracy

±1.0%

Output THDu

<1% (linear load); <5% (non-linear load)

Overload

110%/1h; 125%/10min; 150%/1min; >150%/200ms

Frequency Accuracy

0.1%

Synchronize Window

Settable ±0.5Hz–±5Hz, default ±3Hz

Slew Rate

Settable 0.5Hz/s–3Hz/s, default 0.5Hz/s

Crest Factor

3:1

Phase Accuracy

120° ± 0.5°

System

Efficiency

≥96%

Display

LED + 7" Touch LCD

IP Degree

IP20

Configuration

USB, RS232, RS485, Dry Contact

Option

SNMP Card, Extended Dry Contact Card, Parallel Kit, APP / Wi-Fi / Bluetooth

Environment

0–40°C (operation); −40–70°C (storage); 0–95% RH (non-condensing)

Dimensions (W×D×H mm)

Cabinet Dimension

250*645*555

250*645*555

250*645*555

250*520*580

250*520*580

380*950*900

380*950*900

380*950*900

500*900*1200

500*900*1200

500*900*1200

MAX Dimension

250*772*555

250*772*555

250*772*555

250*620*580

250*620*580

380*1075*900

380*1075*900

380*1075*900

500*900*1200

500*900*1200

500*900*1200

5. Certifications & Compliance

The GT Tower Series three-phase tower UPS is designed and tested in compliance with the following international standards:

  • UPS Safety Standard: IEC 62040-1
  • UPS EMC Standard: IEC 62040-2
  • UPS Performance Standard: IEC 62040-3

6. Interfaces & Optional Accessories

Standard Interfaces

USB, RS232, RS485, Dry Contact — enabling UPS monitoring, graceful server shutdown, Modbus BMS integration, and generator control signaling as standard on all models.

Optional Accessories

  • SNMP Card — SNMP network UPS monitoring and DCIM platform integration.
  • Extended Dry Contact Card — additional relay outputs for generator control, alarm panels, and BMS integration.
  • Parallel Kit — N+1 redundant parallel operation for scalable UPS capacity and system redundancy.
  • APP / Wi-Fi / Bluetooth — wireless UPS monitoring and control via mobile devices.

FREE TO CONTACT US