GOTTOGPOWER 300~600kVA Large Three-Phase Tower UPS
The GT Tower Series 300–600kVA three-phase tower UPS delivers 3P/3P online double-conversion power protection with Full DSP digital control, ≥96% efficiency, ±240VDC battery bus, redundancy fan design, flexible top/bottom cable entry, intelligent fault recording, 10-inch touch LCD management, and wide 40–70Hz generator-compatible input — providing a robust, enterprise-ready large three-phase uninterruptible power supply for data centers, finance, government, industrial, healthcare, and telecommunications critical power infrastructure across four models (GT300, GT400, GT500, GT600).
Classification:
Tower UPS
Inquire Now
Product Description
1. Product Overview
The GT Tower Series 300–600kVA three-phase tower UPS is a large-capacity, high-performance uninterruptible power supply system developed by GOTTOGPOWER (ANHUI) CO., LTD for large enterprise data centers, industrial facilities, financial institutions, and mission-critical national infrastructure requiring robust three-phase online UPS protection at scale. Operating on the 3P/3P Online Double Conversion principle and built around a Full DSP digital control architecture, the GT Tower 300–600kVA three-phase UPS delivers precise, adaptive power conditioning for rectifier, inverter, and battery management across its entire rated power range.
The GT Tower 300–600kVA large UPS system supports 380/400/415V and 50/60Hz power grid systems globally, with a wide input voltage range of 304–478VAC and frequency tolerance of 40–70Hz for reliable operation with both utility grid and diesel generator input. With a ±240VDC battery bus (30–50 batteries, settable), redundancy fan design within the power module, flexible top/bottom cable entry, and a 10-inch LCD touch display, the GT Tower large three-phase UPS is engineered for the highest levels of power infrastructure reliability, maintainability, and deployment flexibility.
2. Key Features
- Full DSP Digital Control — Rectifier, Inverter & Battery Management: Advanced Full DSP (Digital Signal Processor) control architecture delivers flexible, precise, and robust digital management of all three core UPS power conversion stages — enabling superior dynamic response, tighter output regulation, and optimized battery charging across the entire 300–600kVA power range.
- Wide Input Voltage & Frequency Range — Grid & Generator Compatible: The GT Tower 300–600kVA three-phase UPS accepts input voltages from 304–478VAC and frequencies from 40–70Hz, providing reliable uninterruptible power supply operation with both utility grid power and diesel generator input — essential for remote sites, industrial facilities, and data centers with backup generator infrastructure.
- Redundancy Fan Design in Power Module — Enhanced Reliability & Fault Tolerance: Each power module incorporates a redundant fan design, ensuring continued thermal management and full UPS output capability even in the event of an individual fan failure, significantly improving large UPS system reliability and mean time between failures (MTBF).
- Flexible Top/Bottom Cable Entry — Simplified Field Installation: Support for both top and bottom cable entry provides maximum installation flexibility for raised floor, cable tray, and overhead cable management environments, reducing on-site installation complexity and commissioning time for large three-phase UPS deployments.
- Intelligent System Self-Diagnosis & Fault Recording: Comprehensive self-diagnosis engine with rich fault event recording and large-capacity history storage enables proactive UPS maintenance, rapid fault analysis, and minimized mean time to repair (MTTR) for large-scale critical power infrastructure.
- ±3% Voltage Unbalance with 100% Unbalanced Load: The GT Tower UPS maintains output voltage unbalance within ±3% even under 100% unbalanced three-phase loading — ensuring stable power delivery to mixed or asymmetric load configurations typical of large enterprise and industrial environments.
- ≥96% Efficiency — Large-Scale Energy Cost Reduction: High efficiency of ≥96% at full load minimizes cooling requirements and energy costs across large 300–600kVA UPS installations, delivering measurable PUE improvements for data center and industrial facility operators.
3. Typical Applications
The GT Tower Series 300–600kVA three-phase tower UPS is purpose-built for large-scale critical power environments:
- Large Enterprise & Hyperscale Data Center UPS — 300–600kVA three-phase online UPS power protection for large enterprise data centers, colocation facilities, and hyperscale cloud infrastructure requiring high-capacity, redundant uninterruptible power supply.
- Finance & Capital Markets Infrastructure UPS — Large three-phase UPS for major bank data centers, financial exchange infrastructure, trading floor power systems, and payment processing centers with zero tolerance for power interruption.
- Government & National Critical Infrastructure UPS — High-capacity three-phase tower UPS for national data centers, military command facilities, emergency management infrastructure, and government critical IT systems.
- Industrial & Heavy Manufacturing UPS — Large online UPS for large-scale industrial automation, heavy process control, semiconductor fabrication facilities, and mission-critical smart manufacturing infrastructure requiring generator-compatible UPS operation.
- Healthcare & Hospital Campus UPS — Three-phase large UPS for hospital data center power protection, medical imaging infrastructure, laboratory information systems, and campus-wide critical power continuity.
- Telecommunications & Carrier Infrastructure UPS — High-capacity three-phase UPS for carrier-grade telecom exchange centers, national backbone network nodes, data center interconnect facilities, and 5G core network infrastructure.
- Energy & Utilities Control Systems UPS — Large three-phase online UPS for power grid control centers, energy management systems, renewable energy plant control infrastructure, and utility SCADA power protection.
4. Technical Specifications
Models: GT300 · GT400 · GT500 · GT600
Parameter | GT300 300kVA | GT400 400kVA | GT500 500kVA | GT600 600kVA |
Main Input | ||||
Input | 3P5W (3P+N+PE) | |||
Rated Voltage | 380/400/415VAC(L-L) | |||
Frequency Range | 40–70Hz | |||
Input PF | >0.99 | |||
Current Distortion | THDi < 3% (100% Linear load) | |||
Voltage Range | 304~478VAC(L-L) full load; 304~228VAC(L-L) derated 100% to 50% | |||
Battery | ||||
Rated Voltage | ±240 VDC; 30–50 batteries (settable) | |||
Charging Capacity | 20%*Pout | |||
Charging Accuracy | ±1% | |||
Bypass | ||||
Rated Voltage | 380/400/415VAC(L-L) | |||
Voltage Range | Range: −40%~+25%; Settable, default −20%~+15% | |||
Frequency Range | Settable: ±1Hz, ±3Hz, ±5Hz | |||
Inverter Output | ||||
Rated Voltage | 380/400/415VAC(L-L) | |||
Rated Frequency | 50/60Hz | |||
Output PF | 1 | |||
Voltage Accuracy | ±1.0% | |||
Voltage Unbalance | ±3% (with 100% unbalanced load) | |||
Overload Capacity | 110%/1h; 125%/10min; 150%/1min; >150%/200ms | |||
Frequency Accuracy | 0.1% | |||
Synchronize Window | Settable ±0.5Hz–±5Hz, default ±3Hz | |||
Slew Rate | Settable 0.1Hz/s–5Hz/s, default 2Hz/s | |||
Phase Accuracy | 120° ± 0.5° | |||
System | ||||
Efficiency | ≥96% | |||
Display | LED + 10" Touch LCD | |||
IP Degree | IP20 | |||
Safety Certification | IEC62040-1, IEC60950-1 | |||
EMC Certification | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4(EFT); IEC61000-4-5(Surge) | |||
Configuration | USB, RS232, RS485, Dry Contact, Cold Start, Air Filter | |||
Option | SNMP Card, AS400 Card, Parallel Kit, SPD, APP / Wi-Fi / Bluetooth | |||
Environment | 0–40°C (operation); 0–95% RH (non-condensing) | |||
Noise (@1m) | 72dB @ 100% load; 69dB @ 45% load | |||
Dimensions (W*D*H mm) | ||||
Cabinet Dimension | 600*750*2000 | 600*1000*2000 | 600*1000*2000 | 1200*850*2000 |
5. Certifications & Compliance
The GT Tower Series 300–600kVA three-phase tower UPS complies with the following international standards:
- UPS Safety Standard: IEC 62040-1, IEC 60950-1
- UPS EMC Standard: IEC 62040-2
- ESD Immunity: IEC 61000-4-2
- Radiated Susceptibility: IEC 61000-4-3
- Electrical Fast Transient / Burst: IEC 61000-4-4
- Surge Immunity: IEC 61000-4-5
6. Interfaces & Optional Accessories
Standard Interfaces
USB, RS232, RS485, Dry Contact, Cold Start, Air Filter — enabling full UPS monitoring, graceful server shutdown, Modbus BMS integration, generator start/stop control, and protection against dust ingress as standard on all GT Tower 300–600kVA models.
Optional Accessories
- SNMP Card — SNMP network UPS monitoring and DCIM/NMS platform integration for centralized large-scale UPS management.
- AS400 Card — UPS compatibility with IBM AS400 / iSeries mission-critical enterprise server environments.
- Parallel Kit — N+1 redundant parallel operation for scalable large UPS capacity expansion and system redundancy.
- SPD (Surge Protection Device) — additional surge protection for UPS input and output circuits in high-risk electrical environments.
- APP / Wi-Fi / Bluetooth — wireless UPS monitoring and control via mobile devices for flexible on-site management of large UPS installations.