GOTTOGPOWER 800~1200kVA High-Efficiency Three-Phase Tower UPS
The GT Tower Series 800–1200kVA tower UPS is a Full DSP-controlled, >97% efficiency three-phase online double-conversion uninterruptible power supply supporting parallel expansion to 3.2MW — delivering hyperscale data center UPS power protection with intelligent self-diagnosis, 10-inch color LCD touchscreen, three-level system protection, and rapid dynamic response (<5% load transient; <20ms recovery) across three models (GT800, GT1000, GT1200) for large-scale critical power infrastructure worldwide.
Classification:
Tower UPS
Inquire Now
Downloads:
Product Description
1. Product Overview
The GT Tower Series 800–1200kVA tower UPS is a flagship-class, ultra-high-capacity three-phase uninterruptible power supply system developed by GOTTOGPOWER (ANHUI) CO., LTD for hyperscale data centers, national critical infrastructure, and large industrial facilities. Operating on the 3P/3P Online Double Conversion principle with Full DSP digital control over all power conversion stages — rectification, inversion, charging, and discharging — the GT Tower 800–1200kVA large tower UPS delivers industry-leading ≥97% efficiency with rapid dynamic response (<5% load transient; <20ms recovery) at every operating point across its full rated range.
Supporting parallel expansion to a maximum system capacity of 3.2MW, the GT Tower 800–1200kVA UPS is the ideal large-scale tower UPS solution for hyperscale data centers and national infrastructure requiring N+1 redundancy at megawatt scale. Comprehensive three-level protection at system, board, and component levels, combined with intelligent self-diagnosis and large-capacity fault history storage, ensures maximum uptime and minimized MTTR across the complete installation lifecycle.
2. Key Features
- Up to 3.2MW Maximum System Capacity — Hyperscale-Ready Large Tower UPS: Supports parallel expansion to 3.2MW maximum system capacity, making the GT Tower 800–1200kVA the definitive large tower UPS for hyperscale data centers, major financial infrastructure, and national critical power systems requiring megawatt-scale N+1 redundancy.
- ≥97% High-Efficiency Large Three-Phase UPS: Industry-leading ≥97% efficiency at full load reduces energy consumption, cooling infrastructure, and total cost of ownership for 800–1200kVA UPS installations — delivering measurable PUE improvements for data center and industrial facility operators.
- Full DSP Digital Control — Rectification, Inversion, Charging & Discharging: Advanced Full DSP architecture provides simultaneous, precise digital control over all four power conversion stages, enabling superior dynamic performance (<5% load response, <20ms recovery), tight output regulation (±1%), and adaptive battery management.
- Intelligent Self-Diagnosis, Fault Logging & Large-Capacity Historical Data Storage: Comprehensive intelligent self-diagnosis with rich fault event logging and large-capacity historical data storage enables predictive maintenance, rapid root-cause analysis, and minimized MTTR for large-scale mission-critical UPS deployments.
- 10-Inch Color LCD Touchscreen — Enterprise Large UPS Management Interface: Large 10-inch color LCD touchscreen provides real-time visibility of all UPS operational parameters, load profiles, battery status, event logs, and alarm history for efficient on-site large tower UPS management.
- Three-Level Protection — System, Board & Component Reliability: Comprehensive multi-tier protection at system, board, and component levels ensures maximum reliability and enhanced environmental adaptability across the full operational life of the large UPS system.
- Input Derate 100% to 75% — Generator & Weak-Grid Compatible UPS: Maintains 100% rated output with 304–478VAC input, with proportional derating from 100% to 75% as input drops to 228VAC — ensuring reliable large tower UPS operation with both utility grid and diesel generator power under wide disturbance conditions.
3. Typical Applications
The GT Tower Series 800–1200kVA tower UPS is purpose-built for the world's most demanding large-scale critical power environments:
- Hyperscale & Large Enterprise Data Center UPS — 800–1200kVA three-phase tower UPS for Tier III/IV data centers, colocation campuses, and hyperscale cloud infrastructure requiring megawatt-scale uninterruptible power supply with N+1 redundancy up to 3.2MW.
- Financial & Capital Markets Infrastructure UPS — Ultra-high-capacity three-phase UPS for major bank data centers, national financial exchange infrastructure, algorithmic trading platforms, and payment clearinghouse systems with absolute zero-interruption power requirements.
- Government & National Critical Infrastructure UPS — Large tower UPS for national data centers, government cloud platforms, military infrastructure, emergency management systems, and critical national IT requiring maximum system availability.
- Industrial & Heavy Process Manufacturing UPS — High-capacity three-phase online UPS for large-scale industrial automation, petrochemical process control, semiconductor fabrication, and smart manufacturing requiring continuous, generator-compatible uninterruptible power supply.
- Healthcare & Hospital Campus UPS — Large three-phase UPS for major hospital data centers, enterprise medical imaging, clinical research computing, and campus-wide critical medical power continuity at scale.
- Telecommunications & National Network Infrastructure UPS — Large tower UPS for carrier-grade national backbone nodes, major telecom exchange centers, 5G core network infrastructure, and data center interconnect facilities.
- Energy & Power Grid Control UPS — High-capacity online UPS for national power grid control centers, large renewable energy management systems, energy storage dispatch infrastructure, and utility SCADA power protection.
4. Technical Specifications
Parameter | GT800 800kVA/800kW | GT1000 1000kVA/1000kW | GT1200 1200kVA/1200kW |
Main Input | |||
Input | 3P5W (3P+N+PE) | ||
Rated Voltage | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | ||
Rated Frequency | 50/60Hz | ||
Input PF | >0.99 | ||
Current Distortion | THDi < 3% (100% Linear load) | ||
Voltage Range | 304~478VAC(L-L) full load; 304~228VAC(L-L) derated 100% to 75% | ||
Battery | |||
Rated Voltage | ±240 VDC; 30–50 batteries (settable) | ||
Charging Capacity | Max. 15%*Pout | ||
Bypass | |||
Rated Voltage | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | ||
Voltage Range | Range: −40%~+25%; Settable, default −20%~+15% | ||
Overload | 110%, continuous; 110%<load<125%, 5 min; 125%<load<150%, 1 min; >150%, 1 sec | ||
Inverter Output | |||
Rated Voltage | 380/400/415VAC(L-L); 220/230/240VAC(L-N) | ||
Rated Frequency | 50/60Hz | ||
Output PF | 1 | ||
Voltage Accuracy | ±1.0% | ||
Load Response | <5% (20%→80%→20% step load) | ||
Recovery Time | <20ms (0%→100%→0% step load) | ||
Output THDu | <1% (linear load); <5% (non-linear, IEC 62040-3) | ||
Overload | 110%/1h; 125%/10min; 150%/1min; >150%/200ms | ||
Frequency Accuracy | 0.1% | ||
Synchronize Window | Settable ±0.5Hz–±5Hz, default ±3Hz | ||
Slew Rate | Settable 0.5Hz/s–3Hz/s, default 2Hz/s | ||
Crest Factor | 3:1 | ||
Phase Accuracy | 120° ± 0.5° | ||
System | |||
Efficiency | ≥97% | ||
Display | LED + 10" Touch LCD | ||
IP Degree | IP20 | ||
Safety Certification | IEC62040-1, IEC60950-1 | ||
EMC Certification | IEC62040-2; IEC61000-4-2(ESD); IEC61000-4-3(RS); IEC61000-4-4(EFT); IEC61000-4-5(Surge) | ||
Configuration | USB, RS232, RS485, Dry Contact, Cold Start, Air Filter | ||
Option | SNMP Card, AS400 Card, Parallel Kit, SPD, APP / Wi-Fi / Bluetooth | ||
Environment | 0–40°C (operation); −25–70°C (storage); 0–95% RH (non-condensing) | ||
Noise (@1m) | 72dB @ 100% load; 69dB @ 45% load | ||
Dimensions (W*D*H mm) | |||
Cabinet Dimension | 800*1000*2000 | 1200*1100*2000 | 1200*1100*2000 |
5. Certifications & Compliance
The GT Tower Series 800–1200kVA tower UPS complies with the following international standards:
- UPS Safety Standard: IEC 62040-1, IEC 60950-1
- UPS EMC Standard: IEC 62040-2
- ESD Immunity: IEC 61000-4-2
- Radiated Susceptibility: IEC 61000-4-3
- Electrical Fast Transient / Burst: IEC 61000-4-4
- Surge Immunity: IEC 61000-4-5
6. Interfaces & Optional Accessories
Standard Interfaces
USB, RS232, RS485, Dry Contact, Cold Start, Air Filter — enabling UPS monitoring, graceful server shutdown, Modbus BMS/DCIM integration, generator control, and dust protection as standard on all GT800/GT1000/GT1200 models.
Optional Accessories
- SNMP Card — SNMP v1/v2/v3 network UPS monitoring and NMS/DCIM platform integration.
- AS400 Card — UPS compatibility with IBM AS400/iSeries mission-critical enterprise server environments.
- Parallel Kit — N+1 redundant parallel operation enabling system expansion up to 3.2MW.
- SPD (Surge Protection Device) — additional surge protection for UPS input/output circuits.
- APP / Wi-Fi / Bluetooth — wireless UPS monitoring and control via mobile devices.