Getong Energy
+
  • WinnerPro(1-10K)-spec(2465).jpg

WinnerPro(1-10K)

•True double-conversion •Microprocessor control optimizes reliability •Input power factor correction •Output power factor 0.8 •Wide input voltage (110 V – 300 V) •Converter mode available •ECO mode for energy saving (Only available for 1-3KVA) •Generator compatible •Adjustable battery number only available for 6K and up models •Smart SNMP works well with either USB or RS-232 together •Comprehensive display allows easy monitoring and access of UPS status •Optional isolation transformer available. (Please check sales directly)

Classification:

Customized UPS power supply


Product Description

  •True double-conversion

  •Microprocessor control optimizes reliability

  •Input power factor correction

  •Output power factor 0.8

  •Wide input voltage (110 V – 300 V)

  •Converter mode available

  •ECO mode for energy saving (Only available for 1-3KVA)

  •Generator compatible

  •Adjustable battery number only available for 6K and up models

  •Smart SNMP works well with either USB or RS-232 together

  •Comprehensive display allows easy monitoring and access of UPS status

  •Optional isolation transformer available. (Please check sales directly)

MODEL Winner Pro1K (L) Winner Pro 2K (L) Winner Pro 3K (L) Winner Pro 6K (L) Winner Pro 10K (L)
PHASE Single phase with ground
CAPACITY* 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W 6000 VA / 4800 W 10000 VA / 8000 W
INPUT
Nominal Voltage 110/115/120/127VAC or 208/220/230/240VAC 208/220/230/240VAC
Input Voltage Range  55-150 VAC or 110-300 VAC (Based on load at 50%)
85-140VAC or 160-280VAC (Based on load at 100%) 
110-300 VAC (Based on load at 50%)
176-300 VAC (Based on load at 100%)
Frequency Range   40Hz  ~ 70 Hz 46~54 Hz or 56~64 Hz
Power Factor ≧ 0.99 @ Nominal Voltage (100% load)
OUTPUT
Output Voltage 110/115/120/127VAC or 208/220/230/240VAC 208/220/230/240VAC
Voltage Regulation  ± 1%
Frequency Range (Synchronized Range) 47~ 53 Hz or 57 ~ 63 Hz 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≦ 3 % THD (Linear Load)             
≦ 6 % THD (Non-linear Load)
≦ 3 % THD (Linear Load)
≦ 5 % THD (Non-linear Load)
Transfer Time AC Mode to Battery Mode Zero
Inverter to Bypass 4 ms (Typical) Zero
Waveform (Batt. Mode) Pure Sinewave
EFFICIENCY
AC Mode 88% 89% 90% 92% 93%
Battery Mode 83% 87% 88% 90% 91%
BATTERY
Standard Model Battery Type 12 V / 9 AH 12 V / 9 AH 12 V / 9 AH 12 V / 9 Ah
Numbers 2 4 6 16 20 16 20
Typical Recharge Time 4 hours recover to 90% capacity 9 hours recover to 90% capacity
Charging Current (max.) 1A 1A/2A
Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 218.4 VDC ±1% 273 VDC ±1% 218.4 VDC ±1% 273 VDC ±1%
Long-run Model* Battery Type Depending on the capacity of external batteries
Numbers 2 3 4 6 8 6 8 16 ~ 20 (Adjustable)
Charging Current (max.) 1A/2A/4A/6A (Adjustable) 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries)
Charging Voltage 27.4VDC ± 1% 41.0VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 109.4VDC ±1% 82.1 VDC ±1% 109.4VDC ±1% 273 VDC ±1% (Based on 20pcs batteries)
INDICATORS
LCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continously sounding
PHYSICAL
Standard Model Dimension, D x W x H (mm) 282 x 145 x 220 397 x 145 x 220 421 x 190 x 318 369 x 190 x 688 442 x 190 x 688
Net Weight (kgs) 9.8 17 27.6 61 74 66 76
Long-run Model** Dimension, D x W x H (mm) 282 x 145 x 220 397 x 145 x 220 369 x 190 x 318 442 x 190 x 318
Net Weight (kgs) 4.1 6.8 7.4 12 16
ENVIRONMENT
Humidity 20-90 % RH @ 0- 40°C (non-condensing) 0-95% RH @ 0-50°C (non-condensing) 0-95% RH @ 0-40°C (non-condensing)
Noise Level Less than 50dBA @ 1 Meter Less than 55dBA @ 1 Meter Less than 58dBA @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser

 

  *1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 208VAC

  6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC

  **Long-run model is only available in 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA).

  * Product specifications are subject to change without further notice