WinnerPro-3-1(10-20K)
•True double-conversion •Output power factor 0.8 •Wide input voltage range •50Hz frequency converter mode •Emergency power off function (EPO) •Generator compatible •SNMP+USB+RS-232 multiple communications •3-stage extendable charging design for optimized battery performance •Optional maintenance bypass switch
Classification:
Customized UPS power supply
Product Description
•True double-conversion
•Output power factor 0.8
•Wide input voltage range
•50Hz frequency converter mode
•Emergency power off function (EPO)
•Generator compatible
•SNMP+USB+RS-232 multiple communications
•3-stage extendable charging design for optimized battery performance
•Optional maintenance bypass switch

| MODEL | Winner Pro 3/1 10K (L) | Winner Pro 3/1 15K (L) | Winner Pro 3/1 20K(L) | ||||
| PHASE | 3 phase in / 1 phase out | ||||||
| CAPACITY | 10000 VA / 8000 W | 15000 VA / 12000 W | 20000 VA / 16000 W | ||||
| INPUT | |||||||
| Nominal Voltage | 3 x 400 VAC (3Ph+N) | ||||||
| Voltage Range | 190-520 VAC (3-phase) @ 50% load 305-520 VAC (3-phase) @ 100% load |
||||||
| Frequency Range | 46~54 Hz | ||||||
| OUTPUT | |||||||
| Output Voltage | 208/220/230/240VAC | ||||||
| AC Voltage Regulation (Batt. Mode) | ± 1% | ||||||
| Frequency Range (Synchronized Range) | 46~54 Hz | ||||||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz | ||||||
| Current Crest Ratio | 3:1 (max.) | ||||||
| Harmonic Distortion | ≦ 3 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load) | ||||||
| Transfer Time | AC Mode to Batt. Mode | zero | |||||
| Inverter to Bypass | zero | ||||||
| Waveform (Batt. Mode) | Pure Sinewave | ||||||
| EFFICIENCY | |||||||
| AC Mode | 91% | 91% | 91% | ||||
| Battery Mode | 91% | 91% | 91% | ||||
| BATTERY | |||||||
| Standard Model | Battery Type | 12 V / 9 AH | |||||
| Numbers | 16 pcs | 20 pcs | 16 pcs | 20 pcs | 16 pcs x 2 strings | 20 pcs x 2 srtings | |
| Typical Recharge Time | 9 hours recover to 90% capacity | ||||||
| Charging Current (max.) | 1A ± 10% | 1A/2A/4A ± 10% (2A default) | |||||
| Charging Voltage | 218.4 VDC ± 1% | 273 VDC ± 1% | 218.4 VDC ± 1% | 273 VDC ± 1% | 218.4 VDC ± 1% | 273 VDC ± 1% | |
| Long-run Model | Battery Type | Depending on the capacity of external batteries | |||||
| Numbers | 16 pcs | 20 pcs | 16 pcs | 20 pcs | 16 pcs | 20 pcs | |
| Charging Current (max.) | 1A/2A/4A ± 10% (4A default) | ||||||
| Charging Voltage | 218.4 VDC ± 1% | 273 VDC ± 1% | 218.4 VDC ± 1% | 273 VDC ± 1% | 218.4 VDC ± 1% | 273 VDC ± 1% | |
| INDICATORS | |||||||
| LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | ||||||
| ALARM | |||||||
| Battery Mode | Sounding every 4 seconds | ||||||
| Low Battery | Sounding every second | ||||||
| Overload | Sounding twice every second | ||||||
| Fault | Continuously sounding | ||||||
| PHYSICAL | |||||||
| Standard Model | Dimension, D X W X H (mm) | 442 x 190 x 688 | 442 x 190 x 688 | 815 x 250 x 826 | |||
| Net Weight (kgs) | 66 | 76 | 67 | 78 | 125 | 145 | |
| Long-run Model | Dimension, D X W X H (mm) | 442 x 190 x 318 | 442 x 190 x 318 | 575 x 190 x 318 | |||
| Net Weight (kgs) | 15 | 16 | 18.95 | ||||
| ENVIRONMENT | |||||||
| Operation Humidity / Temperature | 0-95 % RH / 0- 40°C | ||||||
| Noise Level | Less than 60dB @ 1 Meter | ||||||
| MANAGEMENT | |||||||
| Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, 7/8, Linux and MAC | ||||||
| Optional SNMP | Power management from SNMP manager and web browser | ||||||
* Product specifications are subject to change without further notice
Previous
Next
Previous
Next