  • Galleon-III-3in3out-(30K-200K)_spec(2479).jpg

Galleon III-3in3out-(30-200K)

•True double-conversion •DSP technology guarantees high performance •Output power factor 1.0 •Active power factor correction in all phases •50Hz/60Hz frequency converter mode •ECO mode operation for energy saving (ECO) •Emergency power off function (EPO) •Generator compatible •SNMP+USB+RS-232 multiple communications •3-stage extendable charging design for optimized battery performance •Adjustable battery numbers for long-run model •Maintenance bypass available •Parallel operation with common battery •Power walk-in function •Optional isolation transformer offers full isolation and complete common mode noise rejection

Classification:

Customized UPS power supply


Product Description

  •True double-conversion

  •DSP technology guarantees high performance

  •Output power factor 1.0

  •Active power factor correction in all phases

  •50Hz/60Hz frequency converter mode

  •ECO mode operation for energy saving (ECO)

  •Emergency power off function (EPO)

  •Generator compatible

  •SNMP+USB+RS-232 multiple communications

  •3-stage extendable charging design for optimized battery performance

  •Adjustable battery numbers for long-run model

  •Maintenance bypass available

  •Parallel operation with common battery

  •Power walk-in function

  •Optional isolation transformer offers full isolation and complete common mode noise rejection

MODEL 30 KL 40KL 60 KL 100KL  120KL   180KL   200KL 
PHASE 3-phase in/3-phase out
CAPACITY 30KVA / 30KW 40KVA /40KW 60KVA / 60KW 100KVA / 100KW 120KVA / 120KW 180KVA / 180KW 200KVA / 200KW
PARALLEL CAPABILITY 4
INPUT
Nominal Voltage 3 x 360/380/400/415 VAC (3Ph+N) 
Voltage Range 110-300 VAC  @ 50% load ; 176-276 VAC   @ 100% load
Frequency Range   40~70 Hz 
Power Factor ≧ 0.99  @ 100% load
Harmonic Distortion (THDi) < 4% at full linear load
OUTPUT
Output Voltage 3 x 360*/380*/400/415 VAC (3Ph+N) 
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50/60 Hz ± 1%
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦2% THD (Linear Load)
≦5% THD (Non-linear Load)
Transfer Time AC mode to Battery mode zero
Inverter to Bypass zero
Waveform (Batt. Mode) Pure Sine Wave
Overload Capability   100-110% for 60 min, 111-125% for 10 min, 126%~150% for 1 min; >150% immediately shutdown
BYPASS
Nominal Voltage 3 x 360/380/400/415 VAC (3Ph+N) 
Voltage Range 305VAC~457VAC
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Overload Capability > 130% 1 minute (default)
EFFICIENCY
AC Mode 95.5%
ECO Mode 98.5%
Battery Mode 94.5%
BATTERY
Standard Model  Battery Type 12V/7Ah 12V/9Ah N/A
Numbers (16+16) x 2 (16+16) x 2
Charging Current (max.) 2A 2A
Charging Voltage +/- 13.65 VDC * N ± 1% (N = 16~20) +/- 13.65 VDC * N ± 1% (N = 16~20)
Long-run Model  Battery Type Depending on application
Numbers 32~40 pcs (Adjustable)
Charging Current (max.) 1-12A, Adjustable 1-12A, Adjustable 1-18A, Adjustable 2-36A, Adjustable 3-54A, Adjustable
Charging Voltage    +/-13.65V*N  (N = 16~20)
INDICATORS
Touch  color LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
PHYSICAL
Standard Model  Dimension, D X W X H (mm) 815 x 300 x 1000 815 x 300 x 1000 N/A
Net Weight (kgs) 207 233
Long-run Model  Dimension, D X W X H (mm) 815 x 300 x 1000 815 x 300 x 1000 815 x 300 x 1000 974 x 600 x 1600
Net Weight (kgs) 56 56 74 250 250 340 345
ENVIRONMENT
Operation Temperature 0-40°C
Operation Humidity <95% and non-condensing
Altitude** 0 ~ 1000m at full load
Noise Level Less than 65 dB @ 1 Meter Less than 70 dB @ 1 Meter Less than 75 dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows®  7/8, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser

 

  *When output voltage is set as 3 x 360VAC or 3 x 380VAC, the output power of the unit will be de-rated to 90%.

  **If the UPS is installed or used in a place where the altitude is higher than maximum height, the output power will be derated 1% per 100m.

  Product specifications are subject to change without further notice.